Indications and Limitations of Coverage
Wireless Capsule Endoscopy of Small Intestine Wireless capsule endoscopy of the small bowel (91110) is considered medically necessary for obscure digestive tract bleeding, the site of which has not previously been identified by upper gastrointestinal endoscopy, colonoscopy, push enteroscopy, nuclear imaging, or radiological procedures. This test is indicated for the following diagnosis for those patients who have undergone complete gastrointestinal studies:
Claims reporting conditions other than those referenced above should be denied as not medically necessary and, therefore, not covered. A participating, preferred or network provider cannot bill the member for the denied service unless the provider has given advance written notice, informing the member that the service may be deemed not medically necessary and providing an estimate of the cost. The member must agree in writing to assume financial responsibility, in advance of receiving the service. The signed agreement should be maintained in the provider's records. Wireless capsule endoscopy is limited to those patients who have undergone complete gastrointestinal studies (i.e., stool specimen, upper gastrointestinal endoscopy, and colonoscopy or barium enema), and such studies fail to reveal a source of bleeding. Medical record documentation must indicate that the member has continuing GI blood loss and anemia secondary to the bleeding. Wireless Capsule Endoscopy of the Esophagus Wireless capsule endoscopy of the esophagus (91111) is considered experimental/investigational. Clinical data are inadequate to permit scientific conclusions regarding the clinical role of esophageal capsule endoscopy. A participating, preferred, or network provider can bill the member for the denied service. Date Last Reviewed - 03/2008 Description Wireless capsule endoscopy is an ingestible telemetric gastrointestinal capsule imaging system that is used for visualization of the small bowel mucosa. It is used in the detection of abnormalities of the small bowel, which are not accessible via standard upper gastrointestinal endoscopy and colonoscopy. A small capsule (approximately 11x30mm) is swallowed and moves through the GI tract propelled by peristalsis, transmitting video pictures. The video images are transmitted to sensors taped to the body and stored on a portable recorder. The strength of the signal is used to calculate the position of the capsule as it passes through the GI tract. Video images are stored on a portable recorder and later downloaded to a computer, from which they may be viewed in real time. The capsule passes naturally from the body with the stool. Since it is disposable, it is not recovered. In November 2004, the Given® Diagnostic System with the PillCamTM ESO Capsule received FDA clearance for the visualization of esophageal mucosa. In the esophagus, the capsule camera has been proposed as a screening technique for Barrett's esophagus associated with gastroesophageal reflux disease (GERD). Evaluation of the esophagus requires limited transit time, and it is estimated that the test takes 20 minutes to perform. Alternative techniques include upper endoscopy. |
|
91110 | 91111 |
Traditional (UCR/Fee Schedule) Guidelines
This medical policy may not apply to FEP. Medical policy is not an authorization, certification, explanation of benefits or a contract. Benefits are determined by the Federal Employee Program. |
Comprehensive / Wraparound / PPO / Major Medical Guidelines
Any reference in this bulletin to non-billable services by a network provider may not be applicable to Major Medical.
Managed Care (HMO/POS) Guidelines
PRN References 02/2003, Wireless Capsule Endoscopy 08/2004, Wireless Capsule Endoscopy eligible for suspected Crohn’s disease 08/2006, Wireless Capsule Endoscopy of the Esophagus Not Covered 12/2006, Coverage for Wireless Capsule Endoscopy Expanded |
Capsule Endoscopy, Clinical Update, American Society for Gastrointestinal Endoscopy, Volume 10, No. 2, 10/2002 Capsule Endoscopy in the Evaluation of Patients with Suspected Small Intestinal Bleeding: Results of a Pilot Study, Gastrointestinal Endoscopy, Volume 56, No. 3, 09/2002 Wireless Capsule Diagnostic Endoscopy for Recurrent Small Bowel Bleeding, New England Journal of Medicine, Volume 344, No. 3, 1/2001 National Blue Cross Blue Shield Association Medical Policy 6.01.33, Wireless Capsule Endoscopy as a Diagnostic Technique in Disorders of the Small Bowel and Esophagus, 04/2007 The Accuracy of PillCam ESO Capsule Endoscopy Versus Conventional Upper Endoscopy for the Diagnosis of Esophageal Varices: A Prospective Three-Center Pilot Study, Endoscopy, Volume 38, Number 1, 2006 Esophageal Capsule Endoscopy Versus Esophagogastroduodenoscopy for Evaluating Portal Hypertension: A Perspective Comparative Study of Performance and Tolerance, Endoscopy, Volume 38, Number 1, 2006. ASGE Technology Status Evaluation Report: Wireless Capsule Endoscopy, Gastrointestinal Endoscopy, Volume 63, Number 4, 04/2006 Blinded Comparison of Esophageal Capsule Endoscopy Versus Conventional Endoscopy for a Diagnosis of Barrett's Esophagus in Patients with Chronic Gastroesophageal Reflux, Gastrointestinal Endoscopy, Volume 65, Number 4, 04/2007 |